Flow Regulation Method Of Piston Pump

Aug 19, 2024

Leave a message

Changing the stroke of the pump: By changing the position of the crank pin, adjusting the clearance between the plunger and the crosshead connection, or using a piston stroke adjustment mechanism to change the stroke of the piston, the flow rate can be adjusted.
Change the pump stroke: When the speed of the drive machine is variable, the speed of the drive machine can be changed to adjust the pump stroke, so that the pump stroke varies between the rated stroke and the minimum stroke, in order to achieve the purpose of adjusting the flow rate.
Bypass regulation: Parallel bypass pipelines are connected to the discharge pipeline of the pump, and the flow rate of the reciprocating pump is regulated by adjusting the opening size of the bypass valve.
Changing the motor speed: Adjusting the flow rate by changing the speed of the magnetic pump motor is suitable for magnetic pumps equipped with frequency converters or adjustable speed motors.
Detailed explanation:

Changing the stroke and number of strokes of the pump: Both methods adjust the flow rate by changing the motion parameters of the piston. Changing the stroke of the pump is achieved by increasing or decreasing the stroke length of the piston to alter the displacement of each reciprocating motion; Changing the pumping frequency is achieved by adjusting the flow rate by changing the number of reciprocating movements of the piston per minute.
Bypass regulation: This method is suitable for reciprocating pumps. By connecting a bypass pipeline in parallel to the discharge pipeline of the pump, excess liquid is returned from the pump outlet to the suction tank or suction pipeline through the bypass pipeline. By adjusting the opening size of the bypass valve, the flow rate of the reciprocating pump can be easily adjusted.
Change motor speed: Control the output flow of the pump by adjusting the motor speed. This method is suitable for magnetic pumps equipped with frequency converters or adjustable speed motors. Adjusting the speed of the motor can quickly and accurately change the flow rate of the pump, with minimal impact on the efficiency of the system.