DG4V-5 Directional Valve - How to Specify One Correctly
DESIGN: 20 / 22
REV : 2026-09
Confirm the interface before anything else
Size 05 is sold under several names depending on who drew the manifold. All of them are the same footprint. Match what your drawing says to the chain below; if the drawing names any one of these, the valve will bolt down.
Fixing bolt centres: 71 mm on AC models, 70 mm on DC models. Gasket mounted, four ports P / A / B / T.
Decode the ordering code block by block
| Block | Reads | What it fixes |
|---|---|---|
| D G 4 V | Directional, gasket mounted, solenoid operated, 315 bar | The V is the pressure rating of ports P, A and B - it is not a size code |
| 5 | ISO 4401 Size 05 | The mounting footprint, and therefore your manifold |
| 1st digit of spool | 0, 1, 2, 3, 6, 7, 8, 11, 13, 22, 23, 31, 33, 52, 56, 521, 561 | Which ports are connected in each spool position |
| A / AL / B / BL / C / N | Spring arrangement | What the spool does when the coil is de-energised. L means a left-hand build |
| J | Spool design letter | Determined by the spool you selected, not a free choice. Permitted on all DC builds except 0A, and on AC builds with 8B, 8BL or 8C spools |
| blank / H / W / Z | Manual override | Plain as standard, H water-resistant, W twist and lock, Z no override |
| U / U1 / U6 / KU / KUP… | Coil housing | No plug, DIN plug, DIN plug with lights, flying leads, AMP, or Deutsch with diode |
| A / C / ED / EK / EH / G / H / HL / OJ / P / NN | Coil rating | AC 50 / 60 Hz voltages and DC voltages from 12 V up to 110 V |
| blank / 57 / S9 | Spool position monitoring | 57 is a switch on single solenoid valves; S9 is the monitoring function |
| 6 / 7 | Tank pressure rating | 6 is 160 bar and AC only; 7 is 210 bar and DC only |
| J06 / J08 / J10 / J12 / J99 | Speed control orifice | 0.6, 0.8, 1.0 or 1.2 mm fitted plug; J99 means the port is blanked |
| 20 – 29 | Design number | Installation dimensions are identical across the whole band |
Fix the hydraulic duty
| Working pressure, P / A / B | 315 bar (4,500 psi) |
| Tank pressure, AC build | 120 bar (1,750 psi) |
| Tank pressure, DC build | 210 bar (3,000 psi) |
| Flow | Not a single figure. Read it off the performance curve for your spool, plotted to 120 L/min (30 US gpm) |
| Duty | Continuous, ED = 100% |
| Ambient temperature | −20 °C minimum. Maximum 70 °C DC, 50 °C on 50 Hz AC, 40 °C on 60 Hz AC |
| Fluid compatibility | Standard build: mineral oil, water-in-oil invert emulsion, phosphate ester. Water glycol needs the AC or F13 prefix |
| Response, 2C spool | Reference point at 40 L/min, 175 bar and 100 per cent rated volts: 30 ms in and 40 ms out on AC, 120 ms and 45 ms on DC |
Match the spool and the spring arrangement
The spool decides the flow logic; the spring decides the fail position. Settle the spring first, because it is the one a safety review will ask about.
Spool functions available: 0A, 0B, 0C, 1B, 1C, 2A, 2B, 2C, 2N, 3B, 3C, 6B, 6C, 6N, 7B, 7C, 8B, 8C, 11B, 11C, 22A, 23A, 31B, 31C, 33B, 33C, 52B, 52C, 56B, 56C, 521B, 521C, 561B and 561C, with L variants throughout.
Choose the electrics
Coils are wet-armature, on ISO 4400 (DIN 43650) connections. They hold in down to 90 per cent of rated voltage. The winding is Class H and the encapsulation Class F.
| G | 12 V DC |
| H | 24 V DC |
| HL | 24 V DC, 32 W coil |
| OJ | 48 V DC |
| P | 110 V DC |
| A / C / ED | 110 / 220 / 240 V AC, 50 Hz |
| EK / EH | 115 / 230 V AC, 60 Hz |
| NN | 24 V AC, 50 Hz |
| - | Other voltages on request |
| U | ISO 4400 mounting, no plug supplied |
| U1 | ISO 4400 with a DIN plug fitted |
| U6 | DIN plug fitted, with indicator lights |
| KU | Flying leads from the top of the solenoid |
| KUP4 | Junior timer (AMP) connector |
| KUP5D2 | Moulded Deutsch connector with diode |
| KUP6D2 | Flying lead with Deutsch connector and diode |
DC full power coils draw 38 W; the HL coil draws 32 W. Protection reaches IEC 144 class IP65 once the plug is correctly fitted with the interface seal in place.
Application fit
Before you fix the code, check that your machine belongs on this list. Each row states the equipment normally involved, the duty the valve performs, and the build that usually gets ordered with it. These are standard applications of the size 05 interface, not named projects.
| Industry | Equipment involved | Duty performed | Build usually ordered |
|---|---|---|---|
| Injection moulding and die casting | Clamping units, ejector plates, core pull cylinders, shot cylinders | Clamp open and close, ejector stroke, core pull, shot sequence | Spring centred C or spring offset A / B, DC coil for the softer shift |
| Machine tools and machining centres | Machine vices, chucks, index tables, tool changers, steady rests | Workholding clamp, pallet indexing, tailstock advance, magazine movement | Detent N where the clamp must stay put, otherwise C |
| Hydraulic power units and test stands | Power packs, valve stands, accumulators, test benches | Circuit selection, unloading, accumulator isolation, step-by-step sequencing | Double solenoid C, DC rated for the higher tank pressure |
| Mobile and construction machinery | Boom cylinders, outriggers, implement circuits, stabilisers | Boom and outrigger sequencing, implement selection, stabiliser set | Single solenoid A or B with the H water-resistant override |
| Metallurgy and heavy industry | Press rams, roll balance cylinders, descaling headers, shears | Ram advance and return, long low-pressure hold, roll positioning | C for the double-ended logic, or N where the position must be held |
| Mining, marine and waste handling | Winches, brakes, slewing drives, hatch covers, balers | Conveyor tensioning, brake release, slew control, deck winch and hatch actuation | A or B with the H override; IP65 confirmed with the plug fitted |
Service parts and reliability
Seal kit for DC builds - part 459058
Orifice plug kit for shift tuning - part 459065
Port orifice kit - part 02-350116
Reliability - MTTFd 150 years to ISO 13849
Design numbers 20 to 29 share the same installation dimensions
Four limits to respect
Flow is not a fixed number. Read it from your spool's curve rather than assuming a headline figure.
Ambient ceilings differ by coil. 70 °C DC, 50 °C on 50 Hz AC, 40 °C on 60 Hz AC.
Below 90 per cent of rated voltage the coil is outside its specification, so check the supply before blaming the valve.
Why this body keeps winning the specification
Selection questions, answered
Still on step 2 or 3? Send the working pressure, the flow you need and what the actuator has to do, and we will work the spool and spring selection with you. Once the code is settled, send it with the quantity and the destination for a price and a lead time.
Data reproduces the published figures for the DG4V-5-20/22 design, ISO 4401 Size 05 solenoid operated directional valve (Danfoss literature BC442274655179en). Rounded and typical, without allowance for tolerances; the nameplate and delivery documents are binding. This selection sheet is an aid to specification and does not replace the manufacturer's own data for safety-related design work. DG4V and other marks belong to their respective owners and appear here only to identify fit and compatibility.
Hot Tags: danfoss dg4v-5-2aj-m-u-h7-29 hydraulic directional control valve for construction machinery, material handling and industrial equipment, China danfoss dg4v-5-2aj-m-u-h7-29 hydraulic directional control valve for construction machinery, material handling and industrial equipment manufacturers, suppliers, factory, compact hydraulic valves, hydraulic valve applications, hydraulic valve bushings, hydraulic valve improvements, hydraulic valve monitors, rotary valves